Incorrect “Degraded status” on HP Array Controller
I tried and worked flawlessly, so for all of you with this error….go and donwload !
Fixes:
Upgrade Requirement:
Recommended – HP recommends users update to this version at their earliest convenience.
The following fixes were added to this release:
- Smart Array Controller incorrectly reports Degraded status: Fixed issue where HP Insight Management WBEM Providers were incorrectly reporting a ‘Degraded’ status for the Smart Array Controllers. This caused VMware vSphere Management Console under Health Status category to display a ‘Warning’ Status (Yellow Exclamation) for the HP Smart Array Controllers. HP System Insight Manager and Insight Control for vCenter and other users of the HP Insight Management WBEM Providers would also report the Smart Array Controller as ‘Degraded’.
- Smart Array physical drive incorrectly reports OK status: Fixed issue where HP Insight Management WBEM Providers were not correctly reporting a not-OK status for a removed drive connected to a Smart Array Controller. This caused HP System Insight Manager, VMware vSphere Management Console, Insight Control for vCenter and other users of the HP Insight Management WBEM Providers to report the physical drive as OK after it was removed.
- Server reports incorrect processor Model: Fixed issue where HP Insight Management WBEM Providers would report an incorrect Processor Model for ProLiant servers and blades. For example: “Intel(R) Family: Intel(R) Xeon(TM) 2.5GHz (x86 Family 179 Model 125 Stepping 7)”” is reported instead of the correct “Intel(R) Family: Intel(R) Xeon(TM) 2.5GHz (x86 Family 179 Model 45 Stepping 7